Skip to content

Comparison

Sheep wool compared with other insulation materials.

Byeco's sheep wool has λD 0.034–0.037 W/(m·K) per the data sheets, at 18–20 kg/m³ depending on the product. It is vapour-open (μ = 1). According to the manufacturer's EPD, it can absorb moisture up to 33% of its own weight without losing its insulating performance. The fibre contains biogenic carbon that, according to the EPD, is released again at end of life. Further down, every figure is shown with the document it comes from, so you can compare it with the declaration for the material you are considering.

  • EPD to EN 15804+A2
  • Fire class to EN 13501-1
  • Stock in Sweden
Close-up of sheep wool insulation showing the fibre structure and edge, with a hand for scale

Short answer

Choose sheep wool when you want a vapour-open material that takes up moisture, or a material that, according to the manufacturer's EPD, can be fitted without protective clothing or a dust mask. Shorter fibres can come loose at cut edges. Choose something else when the only requirement is the most insulation for the money, or when the material itself has to reach a higher fire class than Byeco's sheep wool does.

Close-up of sheep wool insulation showing the fibre structure and edge, with a hand for scale
The fibre structure does both jobs: trapped air insulates and the porous network turns sound energy into heat.

Declared values

Four figures and the document behind each one

The first three figures are stated in an environmental product declaration reviewed by a third party. The fire class comes from classification reports to EN 13501-1. None is taken from a brochure or rounded up.

1

Water vapour diffusion resistance factor μ

1 means fully vapour-open

33%

Moisture uptake, at most

of its own weight, no loss of insulating performance (manufacturer's EPD)

9.94

Biogenic carbon in the fibre

kg C per m³ at 23.26 kg/m³, released at end of life (EPD, module C3)

C-s2, d0

Highest fire class

EN 13501-1, across the range

How we compare

Declared figures, per function

The comparison uses only figures stated in a verified environmental product declaration, a declaration of performance, a European Technical Assessment (ETA) or the manufacturer's own document, with a source for every figure. Where we have converted a figure, for example to per m² or to αw, the source note says so. Thermal insulation is compared per m² at the same thermal resistance, acoustics per m² at the same thickness and mounting. A per-kilo comparison says nothing: a kilo of wool and a kilo of stone wool do not do the same job. Where another material is better, the table says so.

Compare materials

Sheep wool next to what you use today.

Same function, same basis. Pick a material and see the difference.

  • 64%lower fossil climate impact per m² at R = 1 than a stone wool batt, calculated with the data sheet's λD source 1,3,9
  • Noglue, binder or synthetic support fibres in the wool source 1
  • Nodust mask or protective clothing for installation, according to the wool's EPD; shorter fibres can come loose at cut edges. For glass wool, stone wool and wood fibre, the manufacturers specify respiratory protection in some conditions source 1,8,10,12

Climate impact of productionkg CO₂e per m² at R = 1, fossil A1–A3

All 9 materials. Pick one to compare it with sheep wool.

  1. with the data sheet's λD; 0.63 with the ETA's
  2. No EPD to EN 15804+A2

Range between two products

Byeco
Mineral wool
Bio-based
Sheep wool
Byeco Plus +++ · 20 kg/m³
Batt made in Sweden
Two batts

Climate impact of productionkg CO₂e per m² at R = 1, fossil A1–A3

Lower is better

Sheep wool: 0.49 source 1,3with the data sheet's λD; 0.63 with the ETA's
Stone wool: 1.37 source 9Sheep wool is 64% lower
Hemp: 1.28–1.94 source 17,19Sheep wool is 61–75% lower

Performance

Thermal conductivity λDW/(m·K)

Lower is better

Sheep wool: 0.034 source 2,3per the data sheet; the ETA gives 0.043
Stone wool: 0.036 source 9
Hemp: 0.040–0.043 source 18,19

Thickness at R = 5mm

Lower is better

Sheep wool: 170 source 2,3with the data sheet's λD; 215 mm with the ETA's
Stone wool: 180 source 9
Hemp: 200–215 source 18,19

Weight at R = 1kg per m²

Sheep wool: 0.68 source 2,3with the data sheet's λD; 0.86 with the ETA's
Stone wool: 1.06 source 9
Hemp: 1.44–1.85 source 17,19

Material

Bio-based raw material% by weight

Sheep wool: 100% source 1sheep wool
Stone wool: 0% source 9stone
Hemp: At least 85% source 17,19hemp, one of the batts with jute

Additives

Sheep wool: No glue source 1,5No support fibres. The wool is treated against moths (Ionic Protect®)
Stone wool: Binder source 9phenol-formaldehyde-urea under 2%, dust-binding mineral oil under 1%
Hemp: Support fibre source 17,19of PLA or polyester, and soda as fire retardant

Indoor environment

Formaldehyde

Sheep wool: Binds formal­dehyde source 1,3368–69% lower level in a chamber test; no formaldehyde resin
Stone wool: Formal­dehyde resin source 9phenol-formaldehyde-urea in the binder, under 2%
Hemp: No formaldehyde resin source 17,19

In use

Cutting

Sheep wool: By hand source 1cut to length without tools
Stone wool: Knife source 10wide-blade stone wool knife
Hemp: Knife or hand saw source 30insulation knife or serrated hand saw

Protection when installing

Sheep wool: No mask source 1No protective clothing or dust mask; shorter fibres can come loose at cut edges
Stone wool: Respirator source 10in unventilated spaces. Protective clothing and gloves
Hemp: not stated in the source

Moisture

Sheep wool: 33% source 1of its own weight can be absorbed without losing insulating performance
Stone wool: Keeps insulating performance and dimensions in different moisture conditions, according to the manufacturer source 9
Hemp: Must be protected against precipitation and wetting, according to one of the manufacturers source 18

Fire

Fire classEN 13501-1

Sheep wool: D-s2, d0 source 2,4per classification report · E per ETA
Stone wool: A1 source 9non-combustible
Hemp: E source 18,19both products

In a fire

Sheep wool: Chars source 2,4,31does not melt, no flaming droplets; smouldering not assessed
Stone wool: Does not ignite source 9,28melts only above 1,000 °C per the manufacturer
Hemp: Chars source 18,32smouldering not declared

Per m² at R = 1, blown cellulose has a lower fossil climate impact than the wool, glass wool is level and lighter, and mineral wool has a higher fire class. The wool is 64% below the stone wool and below wood fibre, hemp, cork and recycled cotton, and it insulates with the thinnest layer, calculated with the data sheet's λD 0.034. With the ETA's 0.043 it takes 215 mm. The reasons to choose wool are moisture, the fact that it is pure wool, and installation.

How we calculated · 33 sources

Per m² at R = 1 m²K/W, the industry's functional unit; the weight is density × λD × R. The wool is Byeco Plus +++: 20 kg/m³ × λD 0.034 = 0.68 kg per m². λD 0.034 is the data sheet's 90/90 value; ETA-07/0214 gives 0.043 for the same grade and the declaration of performance the test value 0.035. With the ETA's λD, Byeco Standard ++ 0.56, Byeco Plus +++ 0.63, Byeco Pro ++++ 0.69 and Byeco Ultra +++++ 0.79 kg CO₂e per m². R = 5 corresponds to a typical external wall. The declarations come from different programmes and were not produced for direct comparison. Transport to site (A4) is not included; according to the wool's EPD it adds about 31% of A1–A3 at 403 km, and the route to the Nordics is longer. The EPD splits the impact of sheep farming by price (economic allocation), which leaves the wool with 0.023% of it. Flax is shown without a climate figure: no maker of flax insulation has published an EPD to EN 15804+A2 (searched on 15 November 2026 in INIES, IBU, Bau-EPD, EPD Hub, EPD Norge, Environdec and ÖKOBAUDAT). Flax's λ is the makers' λ10 and conductivity group, not λD. Sources checked on 4 and 7 October and 15 November 2026.

  1. BAU-EPD-Isolena-2025-1-Ecoinvent. ISOLENA sheep wool. EN 15804+A2, Tabelle 12: 16.9 kg CO₂e per m³ at 23.26 kg/m³ = 0.727 kg per kg, GWP-fossil A1–A3, scaled by product density as section 6 allows. Composition section 2.1, moisture sections 2.1 and 2.11 (a description, not a tested property), installation without protective clothing or dust mask; shorter fibres can come loose at cut edges. A4 5.25 kg CO₂e per m³ at 403 km. Economic allocation: 0.023% of sheep farming. Valid to 2030-05-12.
  2. ETA-07/0214. OIB 2017-11-17. §3.5.1 λD(23,50): ISOLENA Optimal (Byeco Standard ++), Premium (Byeco Plus +++) and Optimal Plus (Byeco Pro ++++) 0.043, Klemmfilz (Byeco Ultra +++++) 0.036. §3.4.2: Klemmfilz αw 0.85 and Optimal αw 0.75 at 50 mm, mounting A. The ETA states no absorption class; the classes in the table are Byeco's classification to EN ISO 11654. Fire class E.
  3. ISOLENA Premium, data sheet 2026-02-25. The manufacturer's data sheet for Premium (Byeco Plus +++), version 25.02.2026: λD 0.034 W/(m·K) as a 90/90 value (λ90/90 0.03397), 20 kg/m³. ETA-07/0214 gives λD 0.043 for Premium, and the declaration of performance LE/Nr. 003/PRE gives the test value 0.035.
  4. B24219. Classification report from Holzforschung München (TU München), 2024-10-25, valid to 2029-10-25: ISOLENA sheep wool insulation D-s2, d0 at 27–33 mm and 18–31 kg/m³. Covers Byeco Plus +++ (20 kg/m³).
  5. ISOLENA, Ionic Protect. Manufacturer's statement: the wool is treated against moths, the treatment is biocide-free and the long-term test to the EAD is published.
  6. EPD-IES-0026646:003. Glass wool batt for stud walls, λD 0.037. 0.481 kg CO₂e per m² at R = 1 (37 mm, 15.6 kg/m³, 0.58 kg), GWP-fossil A1–A3. Binder 1–10%, other additives 1–5%, 50–60% recycled glass. Valid to 2031-01-13.
  7. NEPD-11644-11594. Glass wool batt, λD 0.035. 0.522 kg CO₂e per m² at R = 1 (35 mm, 17 kg/m³), GWP-fossil A1–A3. Binder 5–10%, 60–70% recycled glass. Valid to 2030-07-08. Passes the French VOC regulation class A+ and AgBB according to the EPD.
  8. Glass wool safety data sheet 2024-08-14. Section 3: phenol-formaldehyde resin binder (Bakelite, CAS 25104-55-6), under 10%. Section 8: gloves and eye protection, P2 respirator where ventilation is inadequate. Section 10: the binder decomposes the first time it is heated above 150 °C.
  9. NEPD-4340-3565-EN. Stone wool batt made in Sweden. 1.37 kg CO₂e per m² at R = 1 (λD 0.036, 1.06 kg), GWP-fossil A1–A3. Phenol-formaldehyde-urea binder under 2%, dust-binding mineral oil under 1%. “Keeps its energy-saving abilities and dimensions in different temperature and moisture conditions.” Valid to 2028-04-05.
  10. Stone wool, handling and storage instructions 2025-03-07. Protective clothing and gloves, respiratory protection in unventilated spaces. Cut with a wide-blade stone wool knife.
  11. NEPD-11234-11178. Wood fibre insulation. 0.512 kg CO₂e per m² at R = 1 (38 mm, 1.90 kg), GWP-fossil A1–A3. Wood 88%, ammonium salts 6.8%, PE/PP support fibre 4.9%. Hygroscopic: takes up and releases moisture with the humidity of the air. λD 0.038 and fire class E per declaration of performance 01-06-01. Valid to 2030-05-27.
  12. Wood fibre insulation, handbook 2024. Cut with an insulation saw or a knife against a cutting board; circular, mitre and sabre saws also work. Safety glasses and respiratory protection for prolonged work.
  13. SHR 23.0053. Flexible wood fibre batt, λD 0.036, EPD in the Dutch NMD database. 1.83 kg CO₂e per m² at R = 1 (36 mm, 50 kg/m³), GWP-fossil A1–A3. 86.5% wood, 9.5% additives, including support fibre (BiCo). Fire class E. Valid to 2029-10-10.
  14. Flexible wood fibre batt, technical data sheet. Raw materials: wood fibre, polyolefin fibre and ammonium sulphate. Cut with an insulation knife, sabre saw, jigsaw or electric cutter; cutting raises dust.
  15. S-P-08311. Blown cellulose insulation. 0.134 kg CO₂e per kg, GWP-fossil A1–A3; vertical cavities 55 kg/m³, λD 0.038 = 2.09 kg per m² at R = 1 (2.47 kg at 65 kg/m³). Around 10% additives, boric acid over 0.1%. Fire class B-s2, d0 from 100 mm per the declaration of performance. Valid to 2028-07-04.
  16. ECHA, boric acid (CAS 10043-35-3). Toxic for reproduction category 1B (H360FD) under CLP Annex VI. On the Candidate List of substances of very high concern (SVHC) since 2010-06-18.
  17. EPD-KSI-20250272-CBA1-EN. Hemp batt, IBU, EN 15804+A2. Declared unit 1 m² at 43 mm, RD = 1.00 m²K/W (1.85 kg): GWP-fossil A1–A3 1.94 kg CO₂e. Hemp fibre 85–95%, PLA support fibre and soda as fire retardant. λD 0.043, 35–48 kg/m³. Valid to 2030-05-14.
  18. ETA-23/0832. DIBt 2025-05-06, hemp batts with and without jute. λD(23,50) 0.043, fire class E. The product must be protected against precipitation, wetting and weathering during transport, storage, installation and in the finished construction.
  19. BAU-EPD-Hempflax-2022-1-GaBi. Hemp batt with jute, Bau EPD, EN 15804+A2. Table 10: GWP-fossil A1–A3 32.1 kg CO₂e per m³ at 36 kg/m³; with λD 0.040 (table 1) that is 1.44 kg and 1.28 kg CO₂e per m² at R = 1. Hemp 66%, jute from recycled sacks 22%, polyester support fibre 8%, soda 4% (table 2). Fire class E. Valid to 2027-11-11.
  20. EPD HUB-0281. Expanded insulation corkboard (ICB), EPD Hub, EN 15804+A2. GWP-fossil A1–A3 82.8 kg CO₂e per m³ at 115 kg/m³ (A1 6.61, A2 5.93, A3 70.2); with λD 0.040 that is 4.60 kg and 3.31 kg CO₂e per m² at R = 1. Cork only: the granules are expanded with steam and bound by the cork's own resin, with no added adhesive. Valid to 2028-02-13. The link goes to a published copy of the EPD. Indoor emissions class A+ to ISO 16000.
  21. Corkboard, TDS CTP-465/002 and ACERMI 03/049/270/22. Technical data sheet May 2026: rigid boards, 1,000 × 500 mm; fire class E to EN 13501-1, water absorption WS under 0.5 kg/m² to EN 1609. ACERMI certificate: λD 0.040 W/(m·K), Euroclass E.
  22. INIES 20231035334. Recycled textile insulation, FDES to NF EN 15804+A2. 1 m² at R = 2.55 (100 mm, 2.00 kg): fossil GWP in production (A1–A3) 2.50 kg CO₂e, i.e. 0.98 kg per m² at R = 1 (0.78 kg). Recycled textile fibres 85% and virgin polyester 15%; 10% fire retardant and 0.8% biocide. λD 0.039 (also ACERMI 14/179/918/9). Sources give different fire classes, so none is shown. Valid to December 2028.
  23. Recycled cotton, installation guide 2014. Cut with an insulation knife with a smooth or slightly wavy blade, or with an angle grinder; sometimes by hand.
  24. Flax insulation, brochure 2022. λ 0.038 W/(m·K) to EN 12667 (λ10), not λD. Fire class C-s2, d0 in an SBI test; conditions not stated. Treated with a fire retardant; the substance is not stated. Density is not published.
  25. Flax insulation, installation guide 2022. Cut with a special knife or an insulation saw. Must be stored dry, installed dry and kept dry after installation.
  26. Flax insulation, retailer product sheet. λ10 0.038 W/(m·K) and conductivity group 040, no λD. Cut with an angle grinder with a metal disc or a toothless special hand saw. Gloves and safety glasses. Must be kept dry and protected from moisture.
  27. Glass wool, installation guide 2015. Cut with an insulation knife against a straightedge, always 5 mm oversize.
  28. Stone wool, manufacturer's website. Manufacturer's statement: the stone wool does not melt below 1,000 °C.
  29. Cellulose, handbook. Blown into walls by authorised contractors; the machine needs a truck within about 10 m and 3 × 16 A power.
  30. Hemp batt, installation guidelines. Cut with an insulation knife or a serrated hand saw; circular and sabre saws are not recommended. FFP2 mask and cut-resistant gloves are recommended.
  31. IWTO, Wool & Fire (2020). Fibre table (CSIRO): wool has a limiting oxygen index (LOI) of 25.2%, ignites at 570–600 °C and does not melt; polyester melts at 252–292 °C. Applies to the fibre, not a finished product.
  32. Brandforsk 2024:3. Bio-based building materials, a review of their fire properties. Wood and bio-based insulation such as hemp char instead of melting; knowledge of how smouldering and extinguishing behave in these materials is limited.
  33. Hegyi et al., Materials 14(9):2443, 2021. Ventilated 119 l test chamber, 0.5 air changes per hour, 23 °C and 50% RH, with formaldehyde supplied continuously. With a 44 mm wool mat in the chamber (90% sheep wool and 10% support fibre, 30.8 kg/m³, another manufacturer's), the level was 24, 32 and 34 µg/m³ on days 1, 3 and 7, against 74–110 µg/m³ in the supplied air: 68–69% lower. After a day without supply, about 13% of what had been taken up was released again; the rest is judged to be chemically bound.

Before you choose

Four questions to ask every supplier

Ask us as well. If a supplier cannot answer all four, you have learned something worth knowing.

  1. 01

    Which lambda applies to the product I am going to fit?

    Ask about the product, not the material class. Thermal conductivity does not track density step by step and is stated per grade, not per family. For Byeco Pro ++++ and Byeco Ultra +++++ the data sheets give a measured λtr, and λD to ETA-07/0214 is 0.043 and 0.036 W/(m·K) respectively. Calculate the U-value with a declared λD.

  2. 02

    Which fire class, to which standard, and at which thickness?

    A class without a standard and a thickness cannot go into a specification. Ask for EN 13501-1 and the tested build-up.

  3. 03

    Is there an environmental product declaration, and who reviewed it?

    An EPD nobody has verified is a brochure. Ask for the programme operator, the standard and the validity period.

  4. 04

    What happens to the material when it gets damp?

    Ask for the water vapour diffusion resistance factor μ and moisture uptake as figures, not the word “breathes”. Those properties decide whether the build-up can dry out.

When sheep wool is the right choice

In favour of sheep wool

  • The build-up has to dry in both directions
  • Refurbishment and building conservation where the layer has to tolerate moisture
  • Carbon accounting where stored carbon counts
  • Fitting without protective clothing or a dust mask according to the manufacturer's EPD, often in occupied houses. Shorter fibres can come loose at cut edges
  • Acoustics where the material also has to insulate

Against it

  • The most insulation for the money is the only requirement
  • The fire requirement is higher than sheep wool can meet
  • Space is so tight that every millimetre counts
  • The build-up needs a load-bearing layer

Next

Already settled on sheep wool?

Then the next question is which density the build-up needs.

Questions and answers

Common questions about comparing insulation

Which insulation is best?

Which insulation is best depends on what the layer has to do, and anyone who answers otherwise is selling something. If the build-up has to dry in both directions, vapour openness matters more than lambda. If a loft is being insulated cheaply, the opposite holds. Set the requirement first, then compare declared figures for the products that meet it.

Does sheep wool insulate as well as mineral wool?

The range has λD 0.034–0.037 W/(m·K) per the data sheets, depending on the product. The comparison uses Byeco Plus +++ with λD 0.034 per the product data sheet; ETA-07/0214 gives 0.043 for the same grade. The glass wool in the comparison has 0.035–0.037 and the stone wool 0.036. At R = 5, 170 mm of sheep wool does the job of 175–185 mm of glass wool. Always compare with the product declaration for the mineral wool you are considering, not with a general figure for the material class.

What does sheep wool insulation cost compared with other materials?

Byeco's standard products are priced in the shop, and the home page shows the starting price for each product. You can buy smaller quantities directly in the shop. For projects you get a price in a quote, along with current stock and lead time. Calculate on landed cost per finished build-up, not per pack, because handling differs between materials.

Can sheep wool grow mould?

The manufacturer of Byeco's sheep wool declares Class 0 against mould growth in a long-term test, that is, mould growth intensity 0 to EAD 040005-00-1201, Annex B. According to the manufacturer's EPD, the wool can also absorb moisture up to 33 per cent of its own weight without losing its insulating performance. No mould test report has been published. We will request the documentation from the manufacturer if you need it for a specification.

Describe the build-up and we will suggest the wool that fits.

You get an answer on density, thickness and width, with the documents that go with them.