Skip to content

Architects and engineers

Specify sheep wool without chasing the paperwork.

Values per product, the fire class with its conditions, the EPD and an indicative price per square metre. All open, no login.

Suggest a time for a technical review
  • EPD valid to 2030-05-12
  • CE · ETA-07/0214
  • Stock in Bollebygd

Typical detail · External wall, horizontal section

123456
Wool thickness
  1. Timber cladding
  2. Battens and air gap
  3. Wind barrier
  4. Byeco Plus +++ 200 mm, 20 kg/m³
  5. Vapour control layer
  6. Plasterboard
λD per ETA
0.043 W/(m·K)
R, wool layer
4.65 m²K/W
Fire class
D⁠-⁠s2, d0

Values per product

Read off the value for the product that will actually be installed. Higher density does not always mean lower λ.

  • Byeco Standard ++

    Manufacturer's designation
    Optimal
    Density
    18 kg/m³
    λ per data sheet, W/(m·K)
    0.037
    λD per ETA-07/0214, W/(m·K)
    0.043
    Fire class
    D-s2, d0
  • Byeco Plus +++

    Manufacturer's designation
    Premium
    Density
    20 kg/m³
    λ per data sheet, W/(m·K)
    0.034
    λD per ETA-07/0214, W/(m·K)
    0.043
    Fire class
    D-s2, d0
  • Byeco Pro ++++

    Manufacturer's designation
    Optimal Plus
    Density
    22 kg/m³
    λ per data sheet, W/(m·K)
    0.035 (measured λtr)
    λD per ETA-07/0214, W/(m·K)
    0.043
    Fire class
    D-s2, d0
  • Byeco Ultra +++++

    Manufacturer's designation
    Klemmfilz
    Density
    30 kg/m³
    λ per data sheet, W/(m·K)
    0.033 (measured λtr)
    λD per ETA-07/0214, W/(m·K)
    0.036
    Fire class
    D-s2, d0
  • Byeco Sheep Wool Felt

    Manufacturer's designation
    Schafwollfilz
    Density
    100 kg/m³
    λ per data sheet, W/(m·K)
    Not stated
    λD per ETA-07/0214, W/(m·K)
    Not stated
    Fire class
    C-s2, d0
  • Byeco Floor Underlay

    Manufacturer's designation
    Tritt­schall­dämmung
    Density
    100 kg/m³
    λ per data sheet, W/(m·K)
    Not stated
    λD per ETA-07/0214, W/(m·K)
    Not stated
    Fire class
    C-s2, d0
Values per product
ProductManufacturer's designationDensityλ per data sheet, W/(m·K)λD per ETA-07/0214, W/(m·K)Fire class
Byeco Standard ++Optimal18 kg/m³0.0370.043D-s2, d0
Byeco Plus +++Premium20 kg/m³0.0340.043D-s2, d0
Byeco Pro ++++Optimal Plus22 kg/m³0.035 (measured λtr)0.043D-s2, d0
Byeco Ultra +++++Klemmfilz30 kg/m³0.033 (measured λtr)0.036D-s2, d0
Byeco Sheep Wool FeltSchafwollfilz100 kg/m³Not statedNot statedC-s2, d0
Byeco Floor UnderlayTritt­schall­dämmung100 kg/m³Not statedNot statedC-s2, d0

Fire

The fire class, with its conditions

The insulation is classified D⁠-⁠s2, d0 and the felt C⁠-⁠s2, d0 to EN 13501-1.

Fire classes across the range on the Euroclass scale from A1 to F.
  • Felt and stripsC-s2, d0
  • InsulationD-s2, d0
  • System: Tested ceiling build-upB-s1, d0

Compare materials

Sheep wool next to what you use today.

Same function, same basis. Pick a material and see the difference.

  • 64%lower fossil climate impact per m² at R = 1 than a stone wool batt, calculated with the data sheet's λD source 1,3,9
  • Noglue, binder or synthetic support fibres in the wool source 1
  • Nodust mask or protective clothing for installation, according to the wool's EPD; shorter fibres can come loose at cut edges. For glass wool, stone wool and wood fibre, the manufacturers specify respiratory protection in some conditions source 1,8,10,12

Climate impact of productionkg CO₂e per m² at R = 1, fossil A1–A3

All 9 materials. Pick one to compare it with sheep wool.

  1. with the data sheet's λD; 0.63 with the ETA's
  2. No EPD to EN 15804+A2

Range between two products

Byeco
Mineral wool
Bio-based
Sheep wool
Byeco Plus +++ · 20 kg/m³
Batt made in Sweden
Two batts

Climate impact of productionkg CO₂e per m² at R = 1, fossil A1–A3

Lower is better

Sheep wool: 0.49 source 1,3with the data sheet's λD; 0.63 with the ETA's
Stone wool: 1.37 source 9Sheep wool is 64% lower
Hemp: 1.28–1.94 source 17,19Sheep wool is 61–75% lower

Performance

Thermal conductivity λDW/(m·K)

Lower is better

Sheep wool: 0.034 source 2,3per the data sheet; the ETA gives 0.043
Stone wool: 0.036 source 9
Hemp: 0.040–0.043 source 18,19

Thickness at R = 5mm

Lower is better

Sheep wool: 170 source 2,3with the data sheet's λD; 215 mm with the ETA's
Stone wool: 180 source 9
Hemp: 200–215 source 18,19

Weight at R = 1kg per m²

Sheep wool: 0.68 source 2,3with the data sheet's λD; 0.86 with the ETA's
Stone wool: 1.06 source 9
Hemp: 1.44–1.85 source 17,19

Material

Bio-based raw material% by weight

Sheep wool: 100% source 1sheep wool
Stone wool: 0% source 9stone
Hemp: At least 85% source 17,19hemp, one of the batts with jute

Additives

Sheep wool: No glue source 1,5No support fibres. The wool is treated against moths (Ionic Protect®)
Stone wool: Binder source 9phenol-formaldehyde-urea under 2%, dust-binding mineral oil under 1%
Hemp: Support fibre source 17,19of PLA or polyester, and soda as fire retardant

Indoor environment

Formaldehyde

Sheep wool: Binds formal­dehyde source 1,3368–69% lower level in a chamber test; no formaldehyde resin
Stone wool: Formal­dehyde resin source 9phenol-formaldehyde-urea in the binder, under 2%
Hemp: No formaldehyde resin source 17,19

In use

Cutting

Sheep wool: By hand source 1cut to length without tools
Stone wool: Knife source 10wide-blade stone wool knife
Hemp: Knife or hand saw source 30insulation knife or serrated hand saw

Protection when installing

Sheep wool: No mask source 1No protective clothing or dust mask; shorter fibres can come loose at cut edges
Stone wool: Respirator source 10in unventilated spaces. Protective clothing and gloves
Hemp: not stated in the source

Moisture

Sheep wool: 33% source 1of its own weight can be absorbed without losing insulating performance
Stone wool: Keeps insulating performance and dimensions in different moisture conditions, according to the manufacturer source 9
Hemp: Must be protected against precipitation and wetting, according to one of the manufacturers source 18

Fire

Fire classEN 13501-1

Sheep wool: D-s2, d0 source 2,4per classification report · E per ETA
Stone wool: A1 source 9non-combustible
Hemp: E source 18,19both products

In a fire

Sheep wool: Chars source 2,4,31does not melt, no flaming droplets; smouldering not assessed
Stone wool: Does not ignite source 9,28melts only above 1,000 °C per the manufacturer
Hemp: Chars source 18,32smouldering not declared

Per m² at R = 1, blown cellulose has a lower fossil climate impact than the wool, glass wool is level and lighter, and mineral wool has a higher fire class. The wool is 64% below the stone wool and below wood fibre, hemp, cork and recycled cotton, and it insulates with the thinnest layer, calculated with the data sheet's λD 0.034. With the ETA's 0.043 it takes 215 mm. The reasons to choose wool are moisture, the fact that it is pure wool, and installation.

How we calculated · 33 sources

Per m² at R = 1 m²K/W, the industry's functional unit; the weight is density × λD × R. The wool is Byeco Plus +++: 20 kg/m³ × λD 0.034 = 0.68 kg per m². λD 0.034 is the data sheet's 90/90 value; ETA-07/0214 gives 0.043 for the same grade and the declaration of performance the test value 0.035. With the ETA's λD, Byeco Standard ++ 0.56, Byeco Plus +++ 0.63, Byeco Pro ++++ 0.69 and Byeco Ultra +++++ 0.79 kg CO₂e per m². R = 5 corresponds to a typical external wall. The declarations come from different programmes and were not produced for direct comparison. Transport to site (A4) is not included; according to the wool's EPD it adds about 31% of A1–A3 at 403 km, and the route to the Nordics is longer. The EPD splits the impact of sheep farming by price (economic allocation), which leaves the wool with 0.023% of it. Flax is shown without a climate figure: no maker of flax insulation has published an EPD to EN 15804+A2 (searched on 15 November 2026 in INIES, IBU, Bau-EPD, EPD Hub, EPD Norge, Environdec and ÖKOBAUDAT). Flax's λ is the makers' λ10 and conductivity group, not λD. Sources checked on 4 and 7 October and 15 November 2026.

  1. BAU-EPD-Isolena-2025-1-Ecoinvent. ISOLENA sheep wool. EN 15804+A2, Tabelle 12: 16.9 kg CO₂e per m³ at 23.26 kg/m³ = 0.727 kg per kg, GWP-fossil A1–A3, scaled by product density as section 6 allows. Composition section 2.1, moisture sections 2.1 and 2.11 (a description, not a tested property), installation without protective clothing or dust mask; shorter fibres can come loose at cut edges. A4 5.25 kg CO₂e per m³ at 403 km. Economic allocation: 0.023% of sheep farming. Valid to 2030-05-12.
  2. ETA-07/0214. OIB 2017-11-17. §3.5.1 λD(23,50): ISOLENA Optimal (Byeco Standard ++), Premium (Byeco Plus +++) and Optimal Plus (Byeco Pro ++++) 0.043, Klemmfilz (Byeco Ultra +++++) 0.036. §3.4.2: Klemmfilz αw 0.85 and Optimal αw 0.75 at 50 mm, mounting A. The ETA states no absorption class; the classes in the table are Byeco's classification to EN ISO 11654. Fire class E.
  3. ISOLENA Premium, data sheet 2026-02-25. The manufacturer's data sheet for Premium (Byeco Plus +++), version 25.02.2026: λD 0.034 W/(m·K) as a 90/90 value (λ90/90 0.03397), 20 kg/m³. ETA-07/0214 gives λD 0.043 for Premium, and the declaration of performance LE/Nr. 003/PRE gives the test value 0.035.
  4. B24219. Classification report from Holzforschung München (TU München), 2024-10-25, valid to 2029-10-25: ISOLENA sheep wool insulation D-s2, d0 at 27–33 mm and 18–31 kg/m³. Covers Byeco Plus +++ (20 kg/m³).
  5. ISOLENA, Ionic Protect. Manufacturer's statement: the wool is treated against moths, the treatment is biocide-free and the long-term test to the EAD is published.
  6. EPD-IES-0026646:003. Glass wool batt for stud walls, λD 0.037. 0.481 kg CO₂e per m² at R = 1 (37 mm, 15.6 kg/m³, 0.58 kg), GWP-fossil A1–A3. Binder 1–10%, other additives 1–5%, 50–60% recycled glass. Valid to 2031-01-13.
  7. NEPD-11644-11594. Glass wool batt, λD 0.035. 0.522 kg CO₂e per m² at R = 1 (35 mm, 17 kg/m³), GWP-fossil A1–A3. Binder 5–10%, 60–70% recycled glass. Valid to 2030-07-08. Passes the French VOC regulation class A+ and AgBB according to the EPD.
  8. Glass wool safety data sheet 2024-08-14. Section 3: phenol-formaldehyde resin binder (Bakelite, CAS 25104-55-6), under 10%. Section 8: gloves and eye protection, P2 respirator where ventilation is inadequate. Section 10: the binder decomposes the first time it is heated above 150 °C.
  9. NEPD-4340-3565-EN. Stone wool batt made in Sweden. 1.37 kg CO₂e per m² at R = 1 (λD 0.036, 1.06 kg), GWP-fossil A1–A3. Phenol-formaldehyde-urea binder under 2%, dust-binding mineral oil under 1%. “Keeps its energy-saving abilities and dimensions in different temperature and moisture conditions.” Valid to 2028-04-05.
  10. Stone wool, handling and storage instructions 2025-03-07. Protective clothing and gloves, respiratory protection in unventilated spaces. Cut with a wide-blade stone wool knife.
  11. NEPD-11234-11178. Wood fibre insulation. 0.512 kg CO₂e per m² at R = 1 (38 mm, 1.90 kg), GWP-fossil A1–A3. Wood 88%, ammonium salts 6.8%, PE/PP support fibre 4.9%. Hygroscopic: takes up and releases moisture with the humidity of the air. λD 0.038 and fire class E per declaration of performance 01-06-01. Valid to 2030-05-27.
  12. Wood fibre insulation, handbook 2024. Cut with an insulation saw or a knife against a cutting board; circular, mitre and sabre saws also work. Safety glasses and respiratory protection for prolonged work.
  13. SHR 23.0053. Flexible wood fibre batt, λD 0.036, EPD in the Dutch NMD database. 1.83 kg CO₂e per m² at R = 1 (36 mm, 50 kg/m³), GWP-fossil A1–A3. 86.5% wood, 9.5% additives, including support fibre (BiCo). Fire class E. Valid to 2029-10-10.
  14. Flexible wood fibre batt, technical data sheet. Raw materials: wood fibre, polyolefin fibre and ammonium sulphate. Cut with an insulation knife, sabre saw, jigsaw or electric cutter; cutting raises dust.
  15. S-P-08311. Blown cellulose insulation. 0.134 kg CO₂e per kg, GWP-fossil A1–A3; vertical cavities 55 kg/m³, λD 0.038 = 2.09 kg per m² at R = 1 (2.47 kg at 65 kg/m³). Around 10% additives, boric acid over 0.1%. Fire class B-s2, d0 from 100 mm per the declaration of performance. Valid to 2028-07-04.
  16. ECHA, boric acid (CAS 10043-35-3). Toxic for reproduction category 1B (H360FD) under CLP Annex VI. On the Candidate List of substances of very high concern (SVHC) since 2010-06-18.
  17. EPD-KSI-20250272-CBA1-EN. Hemp batt, IBU, EN 15804+A2. Declared unit 1 m² at 43 mm, RD = 1.00 m²K/W (1.85 kg): GWP-fossil A1–A3 1.94 kg CO₂e. Hemp fibre 85–95%, PLA support fibre and soda as fire retardant. λD 0.043, 35–48 kg/m³. Valid to 2030-05-14.
  18. ETA-23/0832. DIBt 2025-05-06, hemp batts with and without jute. λD(23,50) 0.043, fire class E. The product must be protected against precipitation, wetting and weathering during transport, storage, installation and in the finished construction.
  19. BAU-EPD-Hempflax-2022-1-GaBi. Hemp batt with jute, Bau EPD, EN 15804+A2. Table 10: GWP-fossil A1–A3 32.1 kg CO₂e per m³ at 36 kg/m³; with λD 0.040 (table 1) that is 1.44 kg and 1.28 kg CO₂e per m² at R = 1. Hemp 66%, jute from recycled sacks 22%, polyester support fibre 8%, soda 4% (table 2). Fire class E. Valid to 2027-11-11.
  20. EPD HUB-0281. Expanded insulation corkboard (ICB), EPD Hub, EN 15804+A2. GWP-fossil A1–A3 82.8 kg CO₂e per m³ at 115 kg/m³ (A1 6.61, A2 5.93, A3 70.2); with λD 0.040 that is 4.60 kg and 3.31 kg CO₂e per m² at R = 1. Cork only: the granules are expanded with steam and bound by the cork's own resin, with no added adhesive. Valid to 2028-02-13. The link goes to a published copy of the EPD. Indoor emissions class A+ to ISO 16000.
  21. Corkboard, TDS CTP-465/002 and ACERMI 03/049/270/22. Technical data sheet May 2026: rigid boards, 1,000 × 500 mm; fire class E to EN 13501-1, water absorption WS under 0.5 kg/m² to EN 1609. ACERMI certificate: λD 0.040 W/(m·K), Euroclass E.
  22. INIES 20231035334. Recycled textile insulation, FDES to NF EN 15804+A2. 1 m² at R = 2.55 (100 mm, 2.00 kg): fossil GWP in production (A1–A3) 2.50 kg CO₂e, i.e. 0.98 kg per m² at R = 1 (0.78 kg). Recycled textile fibres 85% and virgin polyester 15%; 10% fire retardant and 0.8% biocide. λD 0.039 (also ACERMI 14/179/918/9). Sources give different fire classes, so none is shown. Valid to December 2028.
  23. Recycled cotton, installation guide 2014. Cut with an insulation knife with a smooth or slightly wavy blade, or with an angle grinder; sometimes by hand.
  24. Flax insulation, brochure 2022. λ 0.038 W/(m·K) to EN 12667 (λ10), not λD. Fire class C-s2, d0 in an SBI test; conditions not stated. Treated with a fire retardant; the substance is not stated. Density is not published.
  25. Flax insulation, installation guide 2022. Cut with a special knife or an insulation saw. Must be stored dry, installed dry and kept dry after installation.
  26. Flax insulation, retailer product sheet. λ10 0.038 W/(m·K) and conductivity group 040, no λD. Cut with an angle grinder with a metal disc or a toothless special hand saw. Gloves and safety glasses. Must be kept dry and protected from moisture.
  27. Glass wool, installation guide 2015. Cut with an insulation knife against a straightedge, always 5 mm oversize.
  28. Stone wool, manufacturer's website. Manufacturer's statement: the stone wool does not melt below 1,000 °C.
  29. Cellulose, handbook. Blown into walls by authorised contractors; the machine needs a truck within about 10 m and 3 × 16 A power.
  30. Hemp batt, installation guidelines. Cut with an insulation knife or a serrated hand saw; circular and sabre saws are not recommended. FFP2 mask and cut-resistant gloves are recommended.
  31. IWTO, Wool & Fire (2020). Fibre table (CSIRO): wool has a limiting oxygen index (LOI) of 25.2%, ignites at 570–600 °C and does not melt; polyester melts at 252–292 °C. Applies to the fibre, not a finished product.
  32. Brandforsk 2024:3. Bio-based building materials, a review of their fire properties. Wood and bio-based insulation such as hemp char instead of melting; knowledge of how smouldering and extinguishing behave in these materials is limited.
  33. Hegyi et al., Materials 14(9):2443, 2021. Ventilated 119 l test chamber, 0.5 air changes per hour, 23 °C and 50% RH, with formaldehyde supplied continuously. With a 44 mm wool mat in the chamber (90% sheep wool and 10% support fibre, 30.8 kg/m³, another manufacturer's), the level was 24, 32 and 34 µg/m³ on days 1, 3 and 7, against 74–110 µg/m³ in the supplied air: 68–69% lower. After a day without supply, about 13% of what had been taken up was released again; the rest is judged to be chemically bound.

The value to use in a climate declaration

A Swedish climate declaration uses GWP-GHG, without biogenic carbon. With the EPD you use the product's own value instead of Boverket's generic climate data, which is set high on purpose.

GWP-GHG A1–A3, the value a Swedish climate declaration uses
≈ 0.73kg CO₂e/kg
Full life cycle A1–C4, net
+1.12kg CO₂e/kg
Biogenic carbon in the product. Released on incineration (C3)
9.94kg C/m³
EPD valid until
2030-05-12

Indicative prices for the cost estimate

The shop price per square metre for a full pack, for early cost estimates. Project prices and freight are in the quote.

Byeco Standard ++
ThicknessSEK/m² excl. VATincl. VAT
30 mm89111
40 mm118147
50 mm148185
60 mm177222
80 mm235294
100 mm295369
120 mm353442
140 mm412515
Byeco Plus +++
ThicknessSEK/m² excl. VATincl. VAT
150 mm565706
160 mm573717
180 mm644805
200 mm717897
240 mm8601,075
260 mm9321,165
280 mm9931,242
300 mm1,0771,346
Byeco Pro ++++
ThicknessSEK/m² excl. VATincl. VAT
30 mm148185
60 mm296370
Byeco Ultra +++++
ThicknessSEK/m² excl. VATincl. VAT
30 mm148185
40 mm198247
50 mm246308
60 mm296370
80 mm395494
Byeco Sheep Wool Felt
ThicknessSEK/m² excl. VATincl. VAT
9 mm166208
Byeco Floor Underlay
ThicknessSEK/m² excl. VATincl. VAT
3.5 mm7391

Documents

Documentation for your specification

Environmental Product Declaration (EPD)

PDF

Fire classification report for the insulation (EN 13501-1)

Available

European Technical Assessment ETA-07/0214

Available

Declaration of Performance (DoP) for Byeco Standard ++

Available

Declaration of Performance (DoP) for Byeco Plus +++

Available

natureplus® certificate

Available
In progress
  • BIM objects and details
  • BVB, SundaHus and the Nordic Swan product portal

From drawing to wool on site

  1. Send a drawing or specification

    Tell us what the layer has to do: heat, sound, moisture or fire.

  2. Product and thickness proposal

    We propose the product, the thickness and the values that go with it.

  3. Samples and documents

    Samples for the office and the documents for the specification.

  4. Delivery to the contractor

    The contractor orders from stock in Sweden, with the same documentation.

Questions and answers

Questions from architects

Which fire class can I specify for sheep wool?

Byeco's sheep wool insulation is classified D-s2, d0 to EN 13501-1, at about 30 mm mounted directly on a non-combustible substrate. Felt and strips are C-s2, d0. If the assembly needs a higher class, sheep wool is the wrong choice unless the full tested build-up for B-s1, d0 is used.

Which climate value should I use in a climate declaration?

For Byeco's sheep wool insulation, GWP-GHG for A1–A3 is about 0.73 kg CO₂e per kilo, calculated from BAU-EPD-Isolena-2025-1-Ecoinvent as GWP-total minus GWP-biogenic, because the EPD does not report GWP-GHG. Biogenic carbon is not counted in a Swedish climate declaration.

Are there BIM objects for Byeco's sheep wool?

BIM objects for Byeco's sheep wool are not available yet, but they are in progress. Product data and documents are on the site. Tell us if you need an object for a current project.

Is there an AMA Hus specification text for sheep wool?

Yes. Ready-made texts for IBE (external walls), IBF (floor structures) and IBG (roofs) are on the product page for Byeco Sheep Wool Insulation, and the text for the floor underlay is on the product page for Byeco Floor Underlay. The texts are written around performance requirements, so they also work in public procurement where a brand name is followed by “or equivalent”.

We have a moisture consultant on the project. What material data is available?

For the sheep wool, the manufacturer states a water vapour diffusion resistance factor μ = 1, airflow resistivity 4.1–29.5 (kPa·s)/m² and mould growth class 0. Ask for the material data and we will send what the data sheets and the EPD contain.

Can we get samples sent to the office?

Yes. Byeco's sample box (SEK 295 incl. VAT) is ordered from the shop and ships within Sweden. To Norway, Denmark, Finland, Iceland and the Faroe Islands we send samples by arrangement: ask for them in the quote form or email us at info@byeco.se.

Consultation

Talk wool with us.

Thirty minutes on your project, the requirements and what we can supply.